Wet System Valves and Water Motor Alarm

Model AV-1-300  Alarm Check Valve 300 psi (20,7 bar) 2-1/2″ to 8” (DN65 to DN200) Vertical or Horizontal* Installation Features: Sizes 2-1/2″ thru 8” (DN65 thru DN200) AV-1 Alarm Valves may be installed vertically or horizontally Groove x Groove, Flange x Flange, Flange x Groove Alarm Valves are divided seat ring, rubber-faced clapper, check type, water…

Nozzle and Nozzle Accessories

Type EA-1 PROTECTOSPRAY    Directional Spray Nozzles, Automatic, Medium Velocity  Features: Bulb type frangible element for use in closed head systems Discharges a filled cone of water droplets at relatively low velocity The Type EA-1 Nozzles are also especially effective for area coverage and are sometimes used in lieu of standard sprinklers where directional spray…

Special Sprinklers

Model WS Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6K-factor Features:  Only UL tested sprinklers that can protect glazing in a wall or window and allow it to maintain its mechanical equivalent rating up to two hours First sprinklers to be UL/C-UL Listed, ICC-ES, and ULC Listed & Approved for maintaining a rated assembly Pendent…

Dry Sprinklers

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor   Features: Early Suppression, Fast Response (ESFR) The Model ESFR-17 Dry Type Sprinklers are primarily used for ceiling only sprinkler protection and used to protect solid piled, palletized, and rack storage that is subject to freezing temperatures Suppression mode sprinklers that are especially advantageous…

Residential Sprinklers

RAPID RESPONSE Series LFII Residential Sprinklers  Pendent Wet Pipe and Dry Pipe Systems, K-factor=4.9 Features: Intended for use in the following scenarios: Wet and dry pipe residential sprinkler systems for one/two-family dwellings and mobile homes per NFPA 13D Wet and dry pipe residential occupancies up to and including four stories in height per NFPA 13R…

Storage Sprinklers

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers, K-factor=25.2 Features: Early Suppression, Fast Response (ESFR) Suppression-mode sprinklers that are especially advantageous as a means of eliminating the use of in-rack sprinklers when protecting high-piled storage The TYCO Model ESFR-25 Pendent Sprinklers are listed by UL for Specific Applications with a ceiling height greater than 45…

Extended Coverage Sprinklers

Series EC-11 and EC-14 Upright and Pendent Extended Coverage Light and Ordinary Hazard,K-factor=11.2 & 14.0  Features: Light hazard/Ordinary hazard Designed for maximum coverage applications of 400ft2 – 14Ft. x 14Ft. (4,3 m x 4,3 m) up to 20Ft. x 20Ft. (6,1 m x 6,1 m) Low profile decorative glass bulb spray sprinklers Hazard: Light Hazard/Ordinary Hazard Temperature: 135,…

Standard Spray Sprinklers

    Series TY-L   Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage, K-factor=5.6 & 8.0   Features:  All hazards Discharges a hemispherical water spray pattern in the area beneath the sprinkler Designed for use in light, ordinary, and extra hazard, commercial occupancies such as banks, hotels, shopping malls, factories, refineries, chemical plants,…

Fire Detectors: FireClass 460 Series Addressable Detectors

  FireClass FC460 detectors provide the best in class environmental and detection performance with the capability of detecting all fire types. The Range includes an Optical/Heat Multisensor and Optical/Heat/CO Triple Multisensor. Automatic self-testing of each sensor element offers reassurance of operation at all times and the 360º alarm, isolated and fault LED on each detector…